Global distribution and OEM cooperationsale@atombit.cn
BAT3U
Water Sensor Interface ASICs

BAT3U

Three-channel TDS Interface Module

Three-channel TDS and temperature measurement platform for multi-stage water systems.

Downloads
Key Specifications
Interface
UART command control
Supply
3.3 V
Measurement Range
0–2000 ppm TDS

Product capabilities

Evaluate the capabilities that matter in your system

A three-channel TDS and temperature interface for multi-stage purification systems. One device can monitor feed, intermediate and product water while applying temperature correction to each channel.

01

Three-channel TDS detection

Three 0–2000 ppm TDS channels with error below 2% F.S.

02

0–2000 ppm measuring range

Three temperature channels covering 0–60 °C with ±0.5 °C reference accuracy.

03

Automatic temperature correction

3.3 V supply, below 3 mA and UART 9600 bps.

04

Bipolar probe drive

TSSOP20 package with bipolar excitation for each probe channel.

Overview

Product overview

A three-channel TDS and temperature interface for multi-stage purification systems. One device can monitor feed, intermediate and product water while applying temperature correction to each channel.

Three-channel TDS and temperature measurement platform for multi-stage water systems. • Three-channel TDS detection • 0–2000 ppm measuring range • Automatic temperature correction • Bipolar probe drive • UART command interface

Engineering notes

Selection and system integration

  1. 01Three 0–2000 ppm TDS channels with error below 2% F.S.
  2. 02Three temperature channels covering 0–60 °C with ±0.5 °C reference accuracy.
  3. 033.3 V supply, below 3 mA and UART 9600 bps.
  4. 04TSSOP20 package with bipolar excitation for each probe channel.

Technical data

Key Specifications

Use this information for initial selection; confirm final design and purchasing against the current approved datasheet and sample.

Interface
UART command control
Supply
3.3 V
Measurement Range
0–2000 ppm TDS
Accuracy
< 2% F.S.
Temperature
0–60 °C, ±0.5 °C

Application readiness

Installation, calibration and validation

Validate the product with real samples, final mechanics and the intended electrical environment before production.

  1. 01

    Use the same probe model on all three channels.

  2. 02

    Separate simultaneously immersed probes by at least 1 m to reduce interaction.

  3. 03

    Commission and record each channel using the actual plumbing position and expected water range.

Public documents

Datasheets and product documents

Documents are based on AtomBit public product information; confirm the current revision before design release.

Start a project

Find the right sensing product for your project

Share the application, target parameters, installation space, interface and estimated quantity. Our team will recommend a product or customization route.

AtomBit Global Sales

Request product and cooperation information